Home > Product > Pressure Transmitter > Rosemount Pressure Transmitter

Emerson Rosemount 2088 Pressure Transmitter

Emerson Rosemount 2088 Pressure Transmitter
Emerson Rosemount 2088 Pressure Transmitter Product Description With the Rosemount 2088 Gage and Absolute Pressure Transmitter, you can keep on schedule with a quick and easy-to-install solution. This transmitter features a Local Operator Interface (LOI) that has easy-to-use menus and built-in...
Product Details:

Emerson Rosemount 2088 Pressure Transmitter


Product Description


With the Rosemount 2088 Gage and Absolute Pressure Transmitter, you can keep on schedule with

a quick and easy-to-install solution. This transmitter features a Local Operator Interface (LOI) that has

easy-to-use menus and built-in configuration buttons, so you can commission the device on the spot

without complicated tools. This pressure transmitter is also available with manifolds and remote seals.


1. The 2088 pressure transmitter is available with a wide range of options to provide solutions for virtually any application.

 2. The 2088 can be calibrated to ranges as low as 0 to 1.5 psi (0.1 bar) and as high as 0 to 4000 psi (275.8 bar). It can also be used to measure negative pressure ranges. The 2088 measurement capabilities enable reliable use in almost any application.

Reference Accuracy: ± 0.10% of Span

Rangeability: 20:1

Installed Stability of ± 0.10% of URL for 12 months

Protocols available include 4-20mA HART®and 1-5 Vdc HART Low Power


Specifications


Measurement Type

Gage, Absolute

Accuracy

Up to 0.065% of span

Stability

Up to ±0.10% of Upper Range Limit (URL) for 3 years

Warranty

Up to 5-year limited warranty

Rangedown

Up to 50:1

Communication Protocol

4-20 mA HART®, 1-5 V Low Power HART®

Measurement Range

Up to 4,000 psig (275,8 bar) Gage, Up to 4,000 psia (275,8 bar) Absolute

Process Wetted Material

316L SST, Alloy C-276

Diagnostics

Basic Diagnostics

Certifications/Approvals

NSF, NACE®, hazardous location, see full specs for complete list of certifications

 

HTB1U9ZXPVXXXXcvXpXXq6xXFXXXL.jpg

HTB1Q_WPOFXXXXaKXVXXq6xXFXXXO.jpg



Features


Local Operator Interface (LOI) features straightforward menus and built-in configuration buttons for ease-of-use

Factory-assembled and leak-checked integral manifold and remote seal solutions deliver a quick start-up

Available protocols include 4-20 mA HART and 1-5 Vdc HART Low Power for application flexibility

Lightweight, compact design allows for easy installation


UT8aYBLX1NXXXagOFbXe.jpg


CONNECTION STYLES

Direct mount and remote mount connections are engineered to meet a wide variety of measurement needs.

Direct mount connections offer simple installation for mounting transmitters directly to the vessel eliminating

the need for additional transmitter mounting provisions. Remote mount connections consist of a seal attached

to a transmitter via capillary tube and are used in tuned or balanced systems, high temperature installations

and remote transmitter mounting applications.

 

UT8m5RIX0taXXagOFbXW.jpg


ERS SYSTEMS

Electronic Remote Sensor (ERS™) System provides DP Level measurements by calculating differential

pressure from individual pressure readings. This solution eliminates the need for long capillaries and heat

tracing, reducing response time by up to 90%. The sensor system is synchronized for DP calculation, easily connects with cable, and can be independently installed and serviced for simple installation and maintenance.

TUNED SYSTEMS

A Tuned-System™ Assembly measures level using capillaries with two different lengths connected to a transmitter which allows the system to compensate for temperature drift. Typically, one side of the system is directly mounted to the vessel and the other is mounted remotely via a capillary tube. This system saves time and cost during installation by eliminating additional transmitter mounting components and is a great solution for applications with short spans and high pressures.

BALANCED SYSTEMS

Balanced Systems are a reliable solution which consists of two, equal-length capillaries connected between the transmitter and seals. The system eliminates the maintenance concerns of wet or dry legs and are good for horizontal flow and indoor applications with little to no temperature variations.


UT83ulLX0RXXXagOFbXo.jpg

 

REMOTE SEALS

The Diaphragm Seal System protects transmitters from hot, cold, corrosive, erosive or viscous processes.

Seals are available with differential, gage and absolute pressure transmitters. Advanced welding and

assembly techniques prevent weld corrosion and improve seal strength to deliver reliability and performance

in the toughest applications. 

 

UT8RWlIX4JaXXagOFbXr.jpg


THERMAL RANGE EXPANDER

Thermal Range Expander enables pressure and level measurements in high temperature processes.

This seal system uses two different fill fluids, extending the operating range of the transmitter from

temperatures ranging from -75 °C (-103 °F) to 410 °C (770 °F). With an improved response time of

up to 46%, thermal range expanders simplify installation and reduce cost by eliminating impulse piping

and heat tracing.

 

Hot Tags: emerson rosemount 2088 pressure transmitter, manufacturers, suppliers, wholesale, agent, good price, sale
Related Products
Feedback: