Home > Product > Flow Meter > Rotameter

Glass Tube Rotameter Gas Flow Meter

Glass Tube Rotameter Gas Flow Meter
Glass tube rotameter gas flow meter Product Description The series of glass rotor flowmeter is an intergrated product by coneshaped glass tube,Float, flanges. The installation is easy and the flowmeter is adjustable, the flowmeter is used in ranges such as semi-conductor chemicals ect. Large...
Product Details:

Glass tube rotameter gas flow meter


Product Description

The series of glass rotor flowmeter is an intergrated product by coneshaped glass tube,Float, flanges. The

 installation is easy  and the flowmeter is adjustable, the flowmeter is used in ranges such as 

 semi-conductor chemicals ect.


Large range application

It is usually used for low pressure, high temperature sheer liquid or gases without suspending particles and

has been widely employed in various industries e.e petroleum,chemicals, electronics,environmental

protection, power supply and medicine.

 

Glass Rotameter Main Technical Parameters

Model 

LZB-15

LZB-25

LZB-40

LZB-50

LZB-100

DN(mm)

Φ15

Φ25

Φ40

Φ50

Φ100

Measuring ratio 

1:10

1:10

1:10

1:10

1:05

Working pressure(MPa)

≤0.6

≤0.6

≤0.6

≤0.6

≤0.4

Accuracy 

2.5

1.5

1.5

1.5

1.5

Flow range

liquid(m3/h)

16-160(L/h)

40-400(L/h)

0.16-1.6

0.4-4.0


25-250(L/h)

60-600(L/h)

0.25-2.5

0.6-6.0

8-40

40-400(L/h)

100-1000(L/h)




Gas (NM3/h)

0.25-2.5


4-40

10-100

120-600

0.4-4.0

1.6-16

6-66

16-160

200-1000

0.6-6.0

2.5-25




 

HTB1cUvbSpXXXXctaVXX760XFXXXF.png

HTB1ynxcPVXXXXc5XFXX760XFXXX3.gif


The installation of the equipment

  1. Enough room should be available around the equipment for easy maintenance.

  2. For calibration, repair, changing and cleaning of the equipment, by-pass should be fitted along the equipment. (see below picture for detail)

  3. The pipeline should be cleaned for the first time installation.

  4. The pipeline should be immovable before installation of the equipment to prevent damage.

  5. One way check valve should be installed at downstream of the equipment to prevent equipment damage from countercurrent, especially water v-cone.

  6. Filter should be installed at upstream of the equipment when application content particles and dirt to prevent blocking of the pipeline.

  7. Suitable buffer or amount setting device should be installed at upstream of the equipment when the application is in pulsating flow to prevent shaking of the float.

  8. The flow meter should be installed vertically.

Valve should be fitted at upstream and flow control valve should be installed at downstream at 5~10 times distance of the bore size.

 

Hot Tags: glass tube rotameter gas flow meter, manufacturers, suppliers, wholesale, agent, good price, sale
Related Products
Feedback: